FR ES
preload
Duct Pressure Drop Calculator

Duct Pressure Loss Estimator

Optimize Your Ventilation Systems with Precision

Plastec Ventilation's Duct Pressure Loss Calculator is an essential tool for HVAC engineers, ventilation designers, and building professionals. This tool enables you to quickly and accurately calculate pressure losses in your duct networks, ensuring optimal fan sizing and maximum energy efficiency.

Understanding Duct Pressure Loss Calculations

When air flows through a duct system, it encounters resistance, causing a drop in its total pressure. This pressure loss needs to be overcome by the fan or air handling unit to ensure adequate airflow. There are two main types of pressure losses:

  • Friction Loss: Occurs due to the friction between the moving air and the inner surfaces of the ductwork. The longer the duct and the rougher its material, the higher the friction loss.
  • Dynamic Loss (or Minor Loss): Caused by changes in the direction or velocity of the airflow. Fittings like elbows, reducers, enlargements, and branches create turbulence, which dissipates energy and results in pressure loss.

Key Concepts and Definitions:

  • Air Density: \(\rho\) [kg/m³]. Standard: \(1.204\ \text{kg/m}^3\). Mass of air per unit volume (e.g., kg/m³). Standard air density: 1.204 kg/m³.
  • Air Viscosity \(\mu\) [Pa·s]: Air's resistance to flow (e.g., Pa·s). Standard air viscosity: \(1.825 \times 10^{-5}\ \text{Pa·s}\).
  • Airflow Rate \(Q\) [m³/s or CFM]: Volume of air moving through the duct per unit time (CFM or m³/s).
  • Duct Area \(A\) [m²]: Cross-sectional area of the duct.
    • For circular ducts with diameter \[A = \pi \left(\frac{D}{2}\right)^2\]
    • For rectangular ducts with width \(W\) and height \(H\): \[A = W \times H\]
  • Air Velocity \(V\): Speed of air movement. Calculated as: \[V = \frac{Q}{A}\].
  • Hydraulic Diameter ($D_h$): Used for non-circular ducts to convert them into an equivalent circular duct for calculation.
    • For circular ducts: \(\;D_h = D\)
    • For rectangular ducts: \(\;D_h = \frac{2WH}{W+H}\)

Friction Loss Calculation: The Darcy-Weisbach Equation

The primary formula for calculating friction loss in ducts is the Darcy-Weisbach equation:

\[\Delta P_\text{friction} = f \cdot \frac{L}{D_h} \cdot \left(\frac{\rho V^2}{2}\right)\]

Where:

  • \(\Delta P_\text{friction}\) = Pressure loss due to friction [Pa]
  • \(f\) = Darcy friction factor [dimensionless]
  • \(L\) = Length of the duct [m]
  • \(D_h\) = Hydraulic diameter [m]
  • \(\rho\) = Air density [kg/m³]
  • \(V\) = Air velocity [m/s]
Determining the Friction Factor (\(f\))

The friction factor depends on two key parameters:

  1. Reynolds Number (Re): This dimensionless number determines the flow type.

    \[\mathrm{Re} = \frac{\rho V D_h}{\mu}\]

    • If (\(\mathrm{Re} \leq 2300\)), the flow is laminar \[f = \frac{64}{\mathrm{Re}}\].
    • If (\(\mathrm{Re} > 4000\)), the flow is turbulent.
  2. Relative Roughness \(\varepsilon / D_h\): The ratio of duct material's absolute roughness \(\varepsilon\) to the hydraulic diameter \(D_h\).

For turbulent flow, the tool uses the Swamee-Jain equation for the friction factor:

\[f = \frac{0.25}{\left[\log_{10}\!\left(\frac{\varepsilon}{3.7 D_h} + \frac{5.74}{\mathrm{Re}^{0.9}}\right)\right]^2}\]

Dynamic Loss Calculation: The K-Factor Method

Dynamic losses (minor losses) are calculated using loss coefficients (K-factors), which are empirical values for different fitting types.

\[\Delta P_\text{dynamic} = K \cdot \left(\frac{\rho V^2}{2}\right)\]

Where:

  • \(\Delta P_\text{dynamic}\) = Pressure loss due to fittings [Pa]
  • \(K\) = Loss coefficient (K-factor) for the fitting [dimensionless]
  • \(\rho\) = Air density [kg/m³]
  • \(V\) = Reference air velocity [m/s] (from the first duct section)

Total Pressure Loss

The total pressure loss is the sum of all friction losses and dynamic losses:

\[\Delta P_\text{total} = \sum \Delta P_\text{friction} + \sum \Delta P_\text{dynamic}\]

Results are converted from Pascals [Pa] to Inches of Water Column (in. w.c.) using: \[1~\text{Pa} \approx 0.00401463~\text{in. w.c.}\]

Duct Pressure Loss Estimator

Duct Sections

No duct sections added yet.

Fittings (Elbows, Reducers, etc.)

No fittings added yet.

Why Calculate Pressure Loss?

In any ventilation system, air encounters resistance as it flows through ducts, elbows, fittings, and other components. This resistance results in pressure loss that your fan must overcome. Accurate pressure loss calculation allows you to:

  • Select the appropriate fan with adequate static pressure
  • Optimize energy consumption by avoiding oversizing
  • Ensure airflow rates meet ventilation requirements
  • Reduce operating costs over the system's lifetime
  • Prevent` performance issues such as excessive noise or insufficient airflow

How Our Calculator Works

Our tool uses fundamental fluid mechanics principles and industry-recognized equations to provide reliable results:

Friction Losses

Friction losses are calculated using the Darcy-Weisbach equation, which accounts for:

  • Duct length and diameter
  • Material roughness (polypropylene, galvanized steel, etc.)
  • Air velocity and Reynolds number
  • Air density and viscosity

Dynamic Losses (Minor Losses)

Each change in direction or cross-section creates turbulence that dissipates energy. Our calculator includes loss coefficients (K-factors) for:

  • 90° and 45° elbows
  • Reducers and enlargements
  • T-junctions
  • Duct entries and exits
  • Grilles and dampers

Total Pressure Loss

The system automatically sums all losses (friction + dynamic) and provides the total static pressure required, expressed in Pascals (Pa) or inches of water column (in. w.c.).

Typical Applications

This calculator is particularly useful for sizing ventilation systems in:

  • Laboratories and fume hoods: Calculating losses in chemical fume extraction networks
  • Industrial facilities: Sizing corrosive vapor extraction systems
  • Cleanrooms: Optimizing ventilation networks to maintain differential pressures
  • Pharmaceutical facilities: Designing extraction systems compliant with GMP standards
  • Chemical plants: Calculating losses in ducts carrying aggressive gases

Selecting the Right Plastec Fan

When sizing your system with our calculator, remember that Plastec polypropylene fans offer significant advantages for corrosive environments:

  • Corrosion resistance: Non-metallic construction eliminating rust and chemical degradation
  • Lightweight design: Reduced structural loads and simplified installation
  • Durability: UV resistance with HALS additives, UL94-V0 flame retardant compliance
  • Smart controls: Integration with CONTROL E-SEAT, L.COM, and CAPTUR monitoring systems
  • Explosion-resistant options: Carbon-Impregnated Polypropylene (CIP) for hazardous locations
  • Quick delivery: Manufactured within 48 hours

How to Use the Calculator

1

Define your duct sections

Enter diameter (or rectangular dimensions), length, and material.

2

Add your fittings

Select the type and quantity of each fitting (elbows, tees, reducers, etc.).

3

Specify air conditions

Enter volumetric flow rate (CFM or m3/h), temperature, and altitude if necessary.

4

Get your results

The calculator displays losses per section, dynamic losses, and total system loss.

Technical Support and Fan Selection

Once pressure losses are calculated, our technical team can help you:

  • Select the optimal Plastec fan meeting your flow and pressure requirements
  • Verify compatibility with smart control systems (CONTROL E-SEAT, L.COM, CAPTUR)
  • Optimize configuration to maximize energy efficiency
  • Integrate monitoring via MODBUS for real-time supervision

Need Assistance?

Our team of experienced engineers is available to support you in your ventilation projects. Whether you need help interpreting calculator results or designing a complete system, we're here to help.

Contact us today to discuss your project and discover how Plastec Ventilation can optimize your corrosive ventilation systems.

Additional Resources

For a complete ventilation solution, also discover our other tools:

  • Lab Fume Hood Flow Calculator: Quick airflow sizing for fume hoods
  • Fan Selection: Complete range of polypropylene fans and blowers
  • Technical Documentation: Installation guides and technical datasheets
  • Industry Applications: Solutions specific to your sector

Plastec Ventilation - Global leader in corrosion-resistant ventilation solutions with 20+ years of experience serving 80+ countries. Rapid manufacturing (48 hours) of polypropylene fans and blowers for demanding environments.

Plastec ventilation logo