EN ES
preload
Laboratory hood featuring Plastec Polypropylene Ventilation System Laboratory hood featuring Plastec Polypropylene Ventilation System

Extraction des hottes de laboratoire

Corrosion-resistant exhaust fans and blowers for fume hood applications

Laboratory work can release vapors and fumes that require reliable capture and removal at the hood. Selecting the right exhaust fan or blower starts with two requirements: the airflow your hood needs and the duct pressure your system creates. If you’re upgrading an existing lab or designing a new installation, Plastec helps you match the right polypropylene fan or blower to your application and airflow requirements.

Laboratory Hazards and Ventilation Standards

Laboratories routinely use chemicals, solvents and biological materials that can release hazardous vapors into the air. Fume hoods are a critical safety control, capturing and containing these vapors at the source to protect lab personnel during daily work.

Industry standards such as ANSI/ASHRAE 110 and ANSI/AIHA Z9.5 establish key performance expectations for laboratory ventilation, including:

Plastec Polypropylene Blower, explosion and corrosive resistant
  • Face velocity (the speed of air entering the fume hood opening): 100 fpm
  • Exhaust plume height: must extend approximately 10 ft above the roof to support safe dispersion of exhaust air.
  • Exhaust discharge velocity: often on the order of 3,000 fpm to reduce re-entrainment, unless a site-specific dispersion analysis demonstrates equivalent performance.
Plastec Polypropylene Blower, explosion and corrosive resistant

Applications dans tout le laboratoire

Sorbonne

Armoire de sécurité biologique

Armoire de sécurité biologique

Sorbonne à bas débit

Sorbonne à bas débit

Plastec Ventilation Systems Can Be Used In Walk In Fume Hoods

Sorbonne Fume Hood

Plastec Polypropylene Ventilation Systems Are Perfect For  Polypropylene Fume Hood

Sorbonne en Polypropylène

Plastec Polypropylene Ventilation Systems Are Perfect For Chemical fume hood

Hottes pour produits chimiques

Hotte d'aspiration

Hotte d'aspiration

Plastec Polypropylene Ventilation Systems Are Perfect For Extractor Arm

Bras d'aspiration

Plastec Polypropylene Ventilation Systems Are Perfect For Variable Air Volume Fume Hood

Sorbonne à débit variable

Sorbonne pour manipulation de radioisotopes

Sorbonne pour manipulation de radioisotopes

Hotte sans évacuation

Par ou commencer

To choose an exhaust fan or blower for a fume hood application, two criteria must be known:

  • Required hood airflow (CFM): based on hood opening and the face velocity your hood is designed to maintain. Plastec provides a Lab Fume Hood Flow Calculator to estimate required airflow using hood dimensions and face velocity.
  • Total duct pressure: the pressure loss created by ductwork, fitting, and connected components. Plastec also offers a convenient Static Pressure Loss Estimator as part of its suite of calculation tools.
Four Plastec Anti-Corrosive Polypropylene Blowers

Plastec offers several other useful tools for sizing fume hood exhaust blowers, including a Plume Height Calculator

Once the required airflow and pressure values are established, Plastec’s fan selection software ZEPHYR can help you select the exact fan needed for your fume hood application, providing data, graphics and documentation for the appropriate fan.

Créez un compte pour accéder aux
prix et acheter en ligne

Bénéficiez de la livraison gratuite et de la livraison le
lendemain sur tous les ventilateurs et souffleurs !

Créer Un Compte

Solutions

V-Series

Engineered for safe, efficient removal of toxic fumes and corrosive gases, our V-Series exhaust fans deliver high-velocity discharge to protect your facility and personnel. Constructed from seamless, high-density polypropylene, they offer unmatched durability, longevity, and compliance with industry standards across labs in university, hospital, and pharmaceutical environments.

Plastec Polypropylene Blower, explosion and corrosive resistant

Key Features & Benefits

  • Fully Non-Metallic Airstream - No metal parts exposed
  • Code-Compliant Design - Built to ANSI 29.5 NFPA 45, and ASHRAF standards for lab exhaust safety.
  • Efficient, Maintenance-Free Operation - Direct drive IE6 motors deliver 25% higher efficiency with no belts, no coatings, and minimal upkeep.
  • All-in-one System - Includes VFD, HMI, weather cover, and discharge nozzle for easy setup and smooth operation.
Plastec Polypropylene Blower, explosion and corrosive resistant

Shop Industrial Plume Exhaust Blowers

Controllers

Our blowers offer superior airflow regulation, meeting the highest standards of efficiency and reliability. Introducing the L. Solution, upgrade your laboratory management system with top-of-the-line controls built to work seamlessly with your ventilation infrastructure and deliver consistent, effective fume extraction for safer, more efficient operations.

Introducing L. Solution: Upgrade your laboratory management system with top-of-the-line controls engineered to integrate seamlessly with your ventilation infrastructure. Designed for consistent, effective fume extraction, our controls support safer, more efficient operations across your facility.

Plastec Polypropylene Blower, explosion and corrosive resistant
Plastec Polypropylene Blower, explosion and corrosive resistant

- L.Com: Control Up To Three Hoods And Snorkel Arm Hoods

- E-Control: Control Of Air Flow On Each Fume Hood

- Captur: Control Tower, Up To 31 E-Control Or L.Com Units

Laboratory Room With Safe Airflow Using Plastec Ventilation Fans & Blowers Laboratory Room With Safe Airflow Using Plastec Ventilation Fans & Blowers

Custom Configuration Options

PLASTEC blowers can be customized to meet the specific needs of each application. They offer a range of options for things like motor type, fan blade design, and control systems, allowing customers to tailor their blowers to their exact requirements.



Request a consultation

Contacter un consultant

Vous pensez que nos options de ventilation industrielle conviennent parfaitement à votre entreprise, mais vous ne savez pas exactement quel ventilateur choisir ? Nous sommes là pour vous aider.

Nous contacter
Contact Us

Besoin d'une assistance technique?

Restez informé ou envoyez les détails de votre demande en cours.

Suivre votre demande
More Than 1000+ Customers in 80+ Countries

+1000 clients dans +80 pays

Leader in Anti-Corrosive Fans with 20 Years of Experience

Leader en ventilation anticorrosion avec +50 ans d’expérience

In-Stock Systems that Ship within 2 Days

Produits en stock et expédiés sous 2 jours ouvrés

Expert Customer Support and Maintenance

Service client spécialisé et maintenance assurée

V 25 Ventilateur de laboratoire à rejet élevé

V 25 - Conçu pour évacuer les fumées provenant d'environnements hautement corrosifs tels que...

V 25 - Conçu pour évacuer les fumées provenant d'environnements hautement corrosifs tels que les laboratoires, les usines chimiques, les hôpitaux, les universités, etc. La construction entièrement en polypropylène et les parois épaisses assurent une protection maximale contre les acides et la corrosion. Les stabilisateurs de lumière (HALS) augmentent la résistance aux UV. V 25 Performance et spécifications dimensionnelles PDF

100-2100 CFM

V 30 Ventilateur de laboratoire à rejet élevé

V 30 - Conçu pour évacuer les fumées provenant d'environnements hautement corrosifs tels que les ...

V 30 - Conçu pour évacuer les fumées provenant d'environnements hautement corrosifs tels que les laboratoires, les usines chimiques, les hôpitaux, les universités, etc. La construction entièrement en polypropylène et les parois épaisses assurent une protection maximale contre les acides et la corrosion. Les stabilisateurs de lumière (HALS) augmentent la résistance aux UV. V 30 Performance et spécifications dimensionnelles PDF

270-3400 CFM

V 35 Ventilateur de laboratoire à rejet élevé

V 35 - Conçu pour évacuer les fumées provenant d'environnements hautement corrosifs tels que les ...

V 35 - Conçu pour évacuer les fumées provenant d'environnements hautement corrosifs tels que les laboratoires, les usines chimiques, les hôpitaux, les universités, etc. La construction en polypropylène et les parois épaisses assurent une protection maximale contre les acides et la corrosion. Les stabilisateurs de lumière (HALS) augmentent la résistance aux UV. V 35 Performance et spécifications dimensionnelles PDF

500-6400 CFM

STAR Fume Hood Controller

Introducing PLASTEC’s brand new STAR Fume Hood controllers are designed for accurate monitoring a...

Introducing PLASTEC’s brand new STAR Fume Hood controllers are designed for accurate monitoring and control over a fume hood. All of PLASTEC’s new controllers come equipped with an HD digital touchscreen interface and air speed sensor. The STAR Fume Hood Controller is available in multiple options, including Constant Air Volume (CAV), Variable Air Volume with PID Output (VAV PID), and Variable Air Volume with two speed settings (VAV 2-Speed). The CAV controller will monitor and display the ai...

Contrôleurs d’air de hotte de laboratoire

Le type A est pour le contrôle du volume d'air constant (CAV) et est proposé avec : Lumières L...

Le type A est pour le contrôle du volume d'air constant (CAV) et est proposé avec : Lumières LED avec alarme - peuvent être montées horizontalement et verticalement. Affichage numérique avec alarme - ne peut être monté que verticalement. Le type B est conçu pour le contrôle du volume d'air variable (VAV) et est compatible avec les contrôleurs à fréquence variable. Lumières LED avec alarme - peuvent être montées horizontalement et verticalement. Affichage numérique avec alarme - ne peu...

Contrôleurs d’air de hotte de laboratoire

Le type A est pour le contrôle du volume d'air constant (CAV) et est proposé avec : Lumières L...

Le type A est pour le contrôle du volume d'air constant (CAV) et est proposé avec : Lumières LED avec alarme - peuvent être montées horizontalement et verticalement. Affichage numérique avec alarme - ne peut être monté que verticalement. Le type B est conçu pour le contrôle du volume d'air variable (VAV) et est compatible avec les contrôleurs à fréquence variable. Lumières LED avec alarme - peuvent être montées horizontalement et verticalement. Affichage numérique avec alarme - ne peu...

CAPTUR E-SEAT Contrôleurs d’air de hotte de laboratoire

Le type A est pour le contrôle du volume d'air constant (CAV) et est proposé avec : Lumières L...

Le type A est pour le contrôle du volume d'air constant (CAV) et est proposé avec : Lumières LED avec alarme - peuvent être montées horizontalement et verticalement. Affichage numérique avec alarme - ne peut être monté que verticalement. Le type B est conçu pour le contrôle du volume d'air variable (VAV) et est compatible avec les contrôleurs à fréquence variable. Lumières LED avec alarme - peuvent être montées horizontalement et verticalement. Affichage numérique avec alarme - ne peu...